-t [threshold]

Displays all the temperature thresholds, or only the specified temperature
thresholds. The valid values for the [threshold] parameter are:

lowarn

The low-temperature warning threshold.

locrit

The low-temperature critical threshold.

hiwarn

The high-temperature warning threshold.

hicrit

The high-temperature critical threshold.

-a

Displays the ambient temperature of the enclosure.

-f [fan] Displays the status of all the fans, or of only the specified fans. Valid values for

the [fan] parameter are: 1, 2, 3, and so on.

-d [drive_bay]

Displays the status of all the disk drive bays (slots), or of only the specified
disk drive bays. Valid values for the [drive_bay] parameter are: 1, 2, 3, and so
on.

-p [PSU]

Displays the status of all the power supply assemblies, or of only the specified
power supply assemblies. Valid values for the [PSU] parameter are 1, 2, 3,
and so on.

-o

Displays the status of the operator panel.

-c

Displays the status of the controller card.

-e

Displays trace information (for service use only)

-I ID[-U]

Modifies the enclosure ID. The ID must be a four-character alphanumeric
string. The optional -U flag causes the object data manager (ODM) to be
updated to show the change.

-B mode

Modifies all bypass cards to the given mode.

-B card=mode

Modifies the specified bypass cards to be in the given modes. The valid values
for the mode parameter are:

v

Automatic

v

Bypass

v

Inline

v

Open

Valid values for the card parameter are 1, 4, 5, 8, 9, 12, 13, 16.

-S

Resets the “exchanged” flag of the selected FRU.

-S d[drive_bay ...]

Resets the flag for the selected disk drive bay (slot). Valid values for drive_bay
are 1, 2, 3, and so on.