Microcode maintenance, Checking the id and level of the microcode package – Compex Systems Advanced SerialRAID Adapters SA33-3285-02 User Manual

Page 334

Advertising
background image

The second entry instructs the run_ssa_healthcheck shell script to run once each hour.
This shell script causes the SSA adapter to log any errors that might exist in the SSA
subsystem, but that are not causing application programs to fail.

The third entry instructs the run_ssa_encl_healthcheck shell script to run at 30 minutes
past each hour. This shell script searches for SSA enclosures that provide support for
SCSI Enclosure Services (SES). If any of those enclosures detects errors, the shell
script causes entries to be made in the error log .

The fourth entry instructs the run_ssa_link_speed shell script to run at 04:30 each day.
This shell script searches for SSA links that are not running at the best speed. If one is
found, an entry is made in the system error log.

Note: You can use 20-MB-per-second (black) SSA cables to connect

40-MB-per-second SSA nodes. If you do, however, the run_ssa_link_speed shell
script might cause errors to be logged that can be solved only by exchanging the
black cables for 40-MB-per-second cables (blue) SSA cables. If you are using
20-MB-per-second SSA cables to connect 40-MB-per-second SSA nodes,
therefore, delete the run_ssa_link_speed cron entry.

Microcode Maintenance

This section describes how to:

v

Check the ID and the level of the microcode package

v

Maintain the adapter microcode

v

Maintain the disk drive microcode

Checking the ID and Level of the Microcode Package

For some problems, the service request number (SRN) might ask you to check the
microcode package ID or the microcode level before you exchange any
field-replaceable units (FRUs).

To determine the microcode package ID, give the following command:

lsattr -E -l adapter -a ucode

where adapter is the ID of the adapter that you want to check; for example,

ssa0

.

An example of a response to this command is:

ucode 14109100.05.50 Name of adapter code download file False

The microcode package ID is 14109100.05.50

Note: The word “False” shows that this attribute cannot be changed.

To determine the adapter microcode level, use the Display or Change Configuration or
Vital Product Data (VPD) service aid to display the VPD for the adapter (see the

314

User’s Guide and Maintenance Information

Advertising