Examples – Compex Systems Advanced SerialRAID Adapters SA33-3285-02 User Manual

Page 377

Advertising
background image

-S b[card ...]

Resets the flag for the bypass card. Valid values for card are 1, 4, 5, 8, 9, 12,
13, 16.

-S p[PSU ...]

Resets the flag for the selected PSU (power supply assembly). Valid values for
PSU are 1, 2.

-S r

Resets the flag for remote power on (RPO).

-S c

Resets the flag for the controller card.

-S o

Resets the flag for the operator panel.

-T threshold=value

Modifies the specified temperature thresholds to the given values. The valid
values for the [threshold] parameter are:

lowarn

The low-temperature warning threshold.

hiwarn

The high-temperature warning threshold.

The value parameter is a temperature in degrees C.

Examples

v

To display the status of all bypass cards on enclosure0, give the command:

ssaencl -l enclosure0 -b

v

To display the status and VPD of the controller card in enclosure0, give the
command:

ssaencl -l enclosure0 -c -v

v

To modify the ID for enclosure0 to R2D2, give the command:

ssaencl -l enclosure0 -I R2D2

v

To display the contents of disk bay (slot) 8 in enclosure0, give the command:

ssaencl -l enclosure0 -d 8

Chapter 16. Using the SSA Command Line Utilities

357

|
|
|

|
|
|

||

||

||