Dual-host system with primary disk drive missing – Compex Systems Advanced SerialRAID Adapters SA33-3285-02 User Manual

Page 217

Advertising
background image

Dual-Host System with Primary Disk Drive Missing

Figure 30 shows a dual-host system that has just been switched on. The system
contains a RAID-1 array whose primary disk drive is missing. The array remains online,
but in the Exposed state until one of the following occurs:

v

The missing primary disk drive becomes available again before a write operation to
the array occurs. Under this condition, the restored disk drive is returned as the array
primary disk drive, and the array returns to the Good state.

v

A write operation to the array occurs before the missing primary disk drive becomes
available again. Under this condition:

– If a hot spare disk drive is available, that hot spare disk drive automatically

becomes the new primary disk drive, and the array goes into the Rebuilding state.
If the missing primary disk drive then becomes available again, it is rejected.

– If, after the write operation occurs, no hot spare disk drive is available, the array

enters the Degraded state. If the missing primary disk drive then becomes
available again, it is rejected.

Secondary 1

Split Array Resolution

= Primary

System 1

SSA Adapter

Primary 1

System 2

SSA Adapter

Figure 30. Dual-Host System with Primary Disk Drive Missing

Chapter 8. Split-Site Management

197

|
|
|

|
|
|

|
|

|
|
|

|
|
|

|

Advertising