SRN 42524

If a Fast-Write Cache Option Card fails, or is removed from the adapter, the affected
devices are all those that contain unsynchronized data when the cache card fails, or is
removed. To list these devices, type:

ssaraid -l ssaX -Iz -a state=no_cache

where X is the adapter number. Use the recovery procedure that is described for SRN
42521. You must recover all the devices that are listed.

SRN 42525

If a Fast-Write Cache Option Card fails, or is removed from the adapter, the affected
devices are all those that contain unsynchronized data when the cache card fails, or is
removed. To list these devices, type:

ssaraid -l ssaX -Iz -a state=wrong_cache

where X is the adapter number. Use the recovery procedure that is described for SRN
42521. You must recover all the devices that are listed.