0 configuration, 1 menu navigation, Configuration – Rice Lake Static Weighing User Manual

Page 19

Advertising
background image

Configuration

15

3.0

Configuration

To set up and configure the CW-90/CW-90X checkweigher, you will either use the

Menu

key on the front panel or

press the setup switch on the bottom of the indicator. The indicator is defaulted at the factory with the audit trail
jumper (JMP1) in the ON position, allowing configuration access by pressing the

Menu

key. Pressing the

Menu

key

will take you to the Audit menu selection. Use the

ID

( ) and

TARGET

( ) navigation keys to move to other menu

selections. Use the

UNDER

( ) and

OVER

( ) navigation keys to enter and exit menu selections, respectively.

AUDIT

Only displayed if

turned on

from Setup menu

Only displayed if

turned on

from Setup menu

CALIBR

SETUP

TEST

EXIT

ID

ACCUM

BRIGHT

T&D

Figure 3-1.

Table 3-1. Menu Menu Summary

Menu

Function

AUDIT

Audit Trail

Displays the legally relevant (LR) firmware version, configuration count, and calibration count.

CALIBR

Calibrate

Calibrates the scale.

SETUP

Setup

Accesses setup options for the scale, features, serial output, print format, digital inputs and outputs,
and displays the version number.

TEST

Test

Performs a basic test on the A/D, digital inputs and outputs, communication ports, RAM, and
keypad.

EXIT

Exit

Exits Configuration mode and returns to the weigh screen.

T&D

Time & Date

Allows you to view and change time and date.

ACCUM

Accumulator

Displays the current accumulator value.

BRIGHT

Brightness

Adjusts display intensity on a scale from 0 (dimmest) to 7 (brightest).

ID

ID

Allows you to setup or edit IDs.

Menu Mode Navigation Structure

3.1

Menu Navigation

Once you have entered the menus, you can use the front panel buttons to navigate. Note the looped menu structure
shown in Figure 3-1. This provides a shortcut for accessing the rightmost menu items by navigating to the left, and
vice-versa for the opposite side of the menu. This shortcut also holds true for sub-menu navigation.

OVER

UNDER

MENU

ID

ENTER

TARGET

Move UP/
Increment

Value

Move DOWN/

Decrement

Value

Backspace

Enter/Exit

Configuration

Menu

Enter VALUE/

Move DOWN

Move LEFT/

Previous

Move RIGHT/

Next

Figure 3-2. Front Panel Key Functions in Menu Mode

Note

During calibration, the ENTER key acts as a data entry confirmation key. It also acts as an EXECUTE key and
accepts the value upon successful calibration. On the CW-90, the ZERO or CLR key can be used for a
backspace.

Various keys are used as directional keys to navigate through the menus (see Figure 3-2). The

ID

( ) and

TARGET

( ) keys scroll left and right (horizontally) on the same menu level;

OVER

( ) and

UNDER

( ) move up and down

(vertically) to different menu levels. These keys have a directional symbol indicating its menu navigation function.
The

ENTER

key has the same function as

UNDER

( ) when navigating the menu; either will move down to access

sub-categories of a main menu item. When adding or editing data using the CW-90X, the

OVER

( ) and

UNDER

( )

keys will edit the blinking digit. The

ID

( ) and

TARGET

( ) keys navigate to another digit. This also applies to the

CW-90, whose numeric keys can be used to insert a digit to the right of the blinking digit. Press

ENTER

to accept

the data and return to the next menu item.

Note

To exit Configuration and return to weighing, press the MENU key or navigate to the EXIT menu and press
ENTER.