0 print formatting, 1 print formatting commands, Print formatting – Rice Lake Static Weighing User Manual

Page 60

Advertising
background image

56

CW-90/90X Checkweigher

7.0

Print Formatting

The CW-90/CW-90X provides seven print formats,

GFMT, NFMT, ACC.FMT, STRM.FM, BUS.FMT, HDRFMT1

and

HDRFMT2

. These determine the format of the

printed output when the

PRINT

key is pressed or when a

KPRINT

EDP command is received. The

GFMT

and

NFMT

will print to all ports assigned as

DEMAND

in the

TRIGGE

parameter, based on whether a tare is in the

indicator. The

ACCFMT

will print to all

DEMAND

ports

when the

ACCUM

is displayed. The

SFMT

will be sent

as a

STREAM

if

TRIGGE

is set to

STREAM

on any port.

The

HDRFMT

s must be called from another format.

Each print format can be customized to include up to
300 characters of information, such as company name
and address, on printed tickets. You can use the
indicator front panel (

PFORMT

menu), EDP commands,

or the Revolutionconfiguration utility to customize the
print formats.

Note

Print formats are limited to 300 characters.

Press the down arrow to cycle to the previous
character. Press the up arrow to cycle to the

next character. To send a decimal point, enclose it in
brackets e.g., <.> or cycle through the characters until the
decimal point is displayed.

7.1

Print Formatting Commands

Table 7-1 lists commands you can use to format the
gross, net and count print formats. Commands included
in the format strings must be enclosed between < and >
delimiters. Any characters outside of the delimiters are
printed as text on the ticket. Text characters can include
any ASCII character that can be printed by the output
device.

Table 7-1. Print Format Commands

Command

Description

<G>

Gross weight in displayed units

<N>

Net weight in displayed units

<T>

Tare weight in displayed units

<A>

Accumulated weight in displayed units

<CKS>

Status of over/under/accept. O=Over,
U=Under, A=Accept space=Zero band

<CKOV>

Over value

<CKUV>

Under value

<CKTV>

Target value

<CKID>

Loaded ID number

<CKD1>

Description 1

<CKD2>

Description 2

<CKU>

Units

<CKT>

Tare

<AC>

Number of accumulator events (5-digit
counter)

<AD>

Date of last accumulator event

<AT>

Time of last accumulator event

<UID>

Unit ID number

<CN>

Consecutive number

<NLnn>

New line (nn = number of termination (<CR/
LF> or <CR>) characters)*

<SPnn>

Space (nn = number of spaces)*

<SU>

Toggle weight data format (formatted/
unformatted)**

<TI>

Time

<nnn>

ASCII character (nnn - decimal value of ASCII
character). Used for inserting control
characters (STX for example) in the print
stream.

<DA>

Date

<TD>

Time & Date

<H1>

Header 1

<H2>

Header 2

Gross, net, and tare weights are 8 digits in length, including
sign and decimal point, followed by a space and a one- to
five-digit units identifier. Total field length with units identifier
is 10-14 characters. Depending on what units are
configured, the units identifier will be lb/oz, lb, oz, g, or kg.

Gross, net, tare, and accumulator weights can be printed in
any configured weight units by adding the following
modifiers to the gross, net, tare, and accumulator weight
commands: /P (primary units), /D (displayed units), /S
(secondary units), /T (tertiary units). If not specified, the
current displayed units (/D) is assumed. Example: To format
a ticket to show net weight in secondary unitsm, use the
following command: <N/S>.

ID and consecutive number (CN) fields are 1–6 characters in
length, as required.

* If nn is not specified, 1 is assumed. Value must be in the
range 1–99.

** After receiving an SU command, the indicator sends
unformatted data until the next SU command is received.
Unformatted data omits decimal points, leading and trailing
characters.

Command

Description

Table 7-1. Print Format Commands

Advertising
This manual is related to the following products: