Rice Lake Static Weighing User Manual

Page 51

Advertising
background image

Note

Operation

47

9. Using the and keys to increment/decrement the values and the and keys to move between digits,

enter the desired under value. If using the CW-90, you can also use the numeric keypad to enter the desired
under value.

The Under value you are entering is a negative value. However, it will appear to be a lower number than the
Over value because the negative symbol is not displayed. An example of Over/Under negative checkweighing
values as they appear on the display would be Over: 3 (actually recorded as -3) and Under: 1 (actually

recorded -1).

To discard any changes and return to weigh mode, press the Menu button.

10. When the desired value is displayed, press

Enter

.

The decimal point flashes.

11. To change the position of the decimal point, use the and keys until it is in the desired position.

12. Press

Enter

again to accept the value and return to weigh mode.

13. Place the weight on the scale and press the

TARE

key to begin negative checkweighing.

14. Begin removing product from the scale until the Accept band is reached.

15. If

AUTO

was selected in Step 2, the weight will be tared automatically. If

ON

was selected, press

TARE

to

tare the weight.

16. Repeat Steps 14-15 as needed.

Advertising