3 featur menu, regula / indust submenu, Featur menu, regula / indust submenu – Rice Lake Static Weighing User Manual

Page 31

Advertising
background image

Configuration

27

3.4.3

FEATUR Menu, REGULA / INDUST Submenu

REGULA

SNPSHT

DISPLY

INDUST

SCALE

HTARE

NO

YES

ZTARE

NO

YES

KTARE

YES

NO

MTARE

REMOVE

REPLAC

NOTHN

NTARE

NO

YES

CTARE

YES

NO

PRTMOT

NO

YES

PRTPT

NO

YES

PRTHLD

NO

YES

HLDWGH

NO

YES

MOTWGH

NO

YES

AGENCY

NTEP

INDUST

NONE

OIML

OVRBAS

CALIB

SCALE

REGION

CANADA

CHKWGH

Only displayed if INDUST is selected
from the AGENCY parameter

UID

CONSC#

PASSWD

STNDBY

KEYLCK

RECALL

SCALE

FEATUR

SERIAL

DIGI/O

PFORMT

VERS

CONFIG

EXIT

T&D

TEST

SETUP

AUDIT

XXXXXXX

CALIBR

BRIGHT

ACCUM

Only displayed if

turned on

from Setup menu

ID

Only displayed if

turned on

from Setup menu

RTARE

YES

NO

Figure 3-9. FEATUR Menu, REGACY/INDUST Submenu

FEATUR Menu, REGULA / INDUST Submenu

Parameter

Choices

Description

Level 4, REGULA / INDUST submenu

SNPSHT

DISPLY
SCALE

Display or Scale weight source.

HTARE

NO, YES

Allow tare in display hold.

ZTARE

NO, YES

Remove tare on ZERO.

KTARE

YES, NO

Always allow keyed tare.

MTARE

REPLAC
REMOVE
NOTHIN

Multiple tare action.

NTARE

NO, YES

Allow negative or zero tare.

CTARE

YES, NO

Allow CLEAR key to clear tare/accumulator.

RTARE

YES, NO

Round push button tare to the nearest display division.

PRTMOT

NO, YES

Allow print while in motion.

PRTPT

NO, YES

Add PT to keyed tare print.

PRTHLD

NO, YES

Print during display hold.

HLDWGH

NO, YES

Allow weighment during display hold.

MOTWGH

NO, YES

Allow weighment in motion.

Table 3-6. REGACY / INDUST Submenu Parameters