5 negative checkweighing – Rice Lake Static Weighing User Manual

Page 50

Advertising
background image

46

CW-90/90X Checkweigher

To access a saved ID from WeighVault over the network connection,

1. Using the CW-90/CW-90X front panel, press the

ID

key.

2. Use the and keys to select an ID to be loaded.

3. Press the

Enter

key.

The ID is loaded and ready to use.

5.5

Negative Checkweighing

You can use negative checkweighing if you have an item which you want to take weight away from. For example,
if a product on the CW-90/90X weighs 20 pounds and you want to remove weight in 2 pound increments, with
negative checkweighing enabled, the Over value could be set to -3 and the Under value could be set to -1. The
Accept band would therefore be -2, illuminating the green LED when the desired weight is removed from the
product.

MODE

RANGE

TARGWT

TARG%

CHKWGH

ID

OFF

ON

NEGCKW

OFF

ON

AUTO

VALSET

KEYED

PUSH

BOTH

RDONLY

PORT1

PORT2

PORT3

OFF

PORT

DATA

TYPE

OFF

VAULT

BUFFER

SCALE

FEATUR

SERIAL

DIGI/O

PFORMT

VERS

CONFIG

EXIT

T&D

TEST

SETUP

AUDIT

XXXXXXX

CALIBR

BRIGHT

ACCUM

Only displayed if

turned on

from Setup menu

ID

Only displayed if

turned on

from Setup menu

LIGHTS

SOLID

GRAPH

OFF

Select Range Mode

Select ON or AUTO

Note

Negative checkweighing is only operable in Range mode. The Target key is not used.

When entering Over/Under values and printing, the negative symbol is not displayed. These numbers are still
treated as negative values despite the symbol not being displayed. COM port settings are limited to L-Stab,
Demand (only if NEGCKW is set to ON rather than AUTO), and Wait SS (see Figure 3-10 on page 29).

Figure 5-7. CHKWGH Menu

To use negative checkweighing:

1. Ensure

Range

is selected under Mode (See Figure 5-7).

2. Under the NEGCKW parameter, select

ON

or

AUTO

.

Note

Note

If ON is selected, you have to manually tare when the Accept band is reached. If AUTO is selected, it will
automatically tare when the Accept band is reached and is stable.

3. Press the

OVER

key.

4. Using the and keys to increment/decrement the values and the and keys to move between digits,

enter the desired over value. If using the CW-90, you can also use the numeric keypad to enter the desired
over value.

The Over value you are entering is a negative value. However, it will appear to be a higher number than the
Under value on the display because the negative symbol is not displayed. An example of Over/Under negative
checkweighing values as they appear on the display would be Over: 3 (actually recorded as -3) and Under: 1
(actually recorded as -1).

To discard any changes and return to weigh mode, press the Menu button.

5. When the desired value is displayed, press

Enter

. The decimal point flashes.

6. To change the position of the decimal point, use the and keys until it is in the desired position.

7. Press

Enter

again to accept the value and return to weigh mode.

8. Press the

UNDER

key.

Advertising