2 value set: push, 2 target weight mode, 1 value set: keyed – Rice Lake Static Weighing User Manual

Page 44: Value set: push, Value set: keyed

Advertising
background image

Note

40

CW-90/90X Checkweigher

6. Press the

UNDER

key. The UNDER light begins flashing and the value with flashing digit is shown.

7. Using the and keys to increment/decrement the values and the and keys to move between digits,

enter the desired under value. If using the CW-90, you can also use the numeric keypad to enter the desired
under value.

To discard any changes and return to weigh mode, press the Menu button.

8. When the desired value is displayed, press

Enter

. The decimal point flashes.

9. To change the position of the decimal point, use the and keys until it is in the desired position.

10. Press

Enter

again to accept the value and return to weigh mode.

5.1.2

Value Set: Push

To set the over/under values using weight on the scale:

1. Place the weight you want to be determined as “over” on the scale.

2. Press the

OVER

key.

3. The weight is captured and set as the over value.

The display will read

Stored

and the over light flashes.

4. Place the weight you want to be determined as “under” on the scale.

5. Press the

UNDER

key.

6. The weight is captured and set as the under value.

The display will read

Stored

and the under light flashes.

7. The Accept band is set as the gap between the over and under settings. See Figure 5-2 for an example.

5.2

Target Weight Mode

In

Target Weight

mode, the over and under values can only be set by keying in the values. The VALSET parameter

only pertains to setting the target weight value. The Accept band is determined based on a desired target weight.

ACCEPT

UNDER

OVER

8.00

13.00

8.01-12.99

Under = 2.00
Over = 3.00
Target = 10.00

Figure 5-3. Example of Under/Over/Target Settings in Target Weight Mode.

5.2.1

Value Set: Keyed

1. Press the

TARGET

key. The Accept light begins flashing and a flashing digit is shown.

2. Using the and keys to increment/decrement the values and the and keys to move between digits,

enter the desired value. If using the CW-90, you can also use the numeric keypad to enter the desired target
weight
value.

Note

Note

To discard any changes and return to weigh mode, press the Menu button.

3. When the desired value is displayed, press

Enter

.

The decimal point flashes.

4. To change the position of the decimal point, use the and keys until it is in the desired position.

5. Press

Enter

again to accept the value and return to weigh mode.

6. Press the

OVER

key. The Over light begins flashing and a flashing digit is shown.

7. Using the and keys to increment/decrement the values and the and keys to move between digits,

enter the desired value. If using the CW-90, you can also use the numeric keypad to enter the desired over
value.

To discard any changes and return to weigh mode, press the Menu button.

Advertising