2 customizing print formats, 1 using the edp port, 2 using the front panel – Rice Lake Static Weighing User Manual

Page 61: Using the edp port, Using the front panel

Advertising
background image

Print Formatting

57

The default CW-90/CW-90X print formats are shown in
Table 7-2:

Table 7-2. GFMT, NFMT, H1, H2, BUF, and ACC Formats

Format

Default Format String

Sample Output

GFMT

<G> GROSS<NL>

2046.81 lb GROSS

NFMT

<G> GROSS<NL>
<T> TARE<NL>
<N> NET<NL>

4053.1 lb GROSS
15.6 lb TARE
4037.5 lb NET

H1

Company Name
<NL> Street Address
<NL> City, ST ZIP
<NL2>

Company Name, Street
Address, City, ST ZIP

H2

Company Name
<NL> Street Address
<NL> City, ST ZIP
<NL2>

Company Name, Street
Address, City, ST ZIP

BUF.FMT

<CKID><G><NL>

ID1 3.00 lb

ACC.FMT

ACCUM<A><NL>

<DA><TI><NL>

ACCUM 27.00 lb

06/03/2010 10:01AM

Note

The 300-character limit of each print format
string includes the output field length of the
print formatting commands, not the command

length. For example, if the indicator is configured to show
a decimal point, the <G> command generates an output
field of 13 characters: the 10-character weight value
(including decimal point), one space, and a two-digit units
identifier.

7.2

Customizing Print Formats

The following sections describe procedures for
customizing the

GFMT

,

NFMT

and

CFMT

formats using

the EDP port, the front panel (

PFORMT

menu), and the

Revolution configuration utility.

7.2.1

Using the EDP Port

With a personal computer, terminal, or remote
keyboard attached to the CW-90/CW-90X EDP port,
you can use the EDP command set to customize the
print format strings.

To view the current setting of a format string, type the
name of the string (

GFMT

or

NFMT

) and press

Enter

. For

example, to check the current configuration of the

GFMT

format, type

GFMT

and press

Enter

. The indicator

responds by sending the current configuration for the
gross format:

GFMT=<G> GROSS<NL>

To change the format, use the

GFMT

or

NFMT

EDP

command followed by an equals sign (=) and the
modified print format string. For example, to add the
name and address of a company to the gross format,
you could send the following EDP command:

Note

Indicator must be placed in the config mode
with CONFIG shown on the display.

GFMT=FINE TRANSFER CO<NL>32400 WEST
HIGHWAY ROAD<NL>SMALLTOWN<NL2><G>
GROSS<NL>

A ticket printed using this format might look like the
following:

FINE TRANSFER CO
32400 WEST HIGHWAY ROAD
SMALLTOWN

1345 lb GROSS

7.2.2

Using the Front Panel

If you have no access to equipment for communication
through the EDP port or are working at a site where
such equipment cannot be used, you can use the

PFORMT

menu (see Figure 7-1) to customize the print

formats.

Using the

PFORMT

menu, you can edit the print format

strings by changing the decimal values of the ASCII
characters in the format string.

Note

Lower-case letters and some special
characters cannot be displayed on the CW-90/
CW-90X front panel and are shown as blanks.

The CW-90/CW-90X can send or receive any ASCII
character; the character printed depends on the particular
ASCII character set implemented for the receiving device.

Advertising