Power - ac, Power - dc, Analog specifications – Rice Lake Static Weighing User Manual

Page 73: Serial communications, Operator interface, Environmental, Enclosure, Certifications and approvals

Advertising
background image

Appendix

69

Power - AC

Line Voltages

115 or 230 VAC

Frequency

50 or 60 Hz

Power Consumption

1.5 A @ 115 VAC (8W)
0.75 A @ 230 VAC (8W)

Fusing

2.5 A 5 x 20 mm fuse

Power - DC

Line Voltages

9-36 VDC DC Input

Power Consumption

1.5 A Max

Fusing

Internal short circuit protection

Analog Specifications

Full Scale Input Signal Up to 22.5 mV
Excitation Voltage

+5V single sided
8 x 350

 or 16 x 700 load cells

Sense Amplifier

Differential amplifier with
4- and 6-wire sensing

Analog Signal

Input Range

–0.5 mV/V to +4.5 mV/V

Analog Signal

Sensitivity

0.3

V/graduation minimum,

1.5

V/grad recommended

Input Impedance

200 M

, typical

Noise (ref to input)

0.3

V p-p with digital filters at 4-4-4

Internal Resolution

8,000,000 counts

Display Resolution

100 000 dd

Measurement Rate

Up to 60 measurements/sec

Input Sensitivity

10 nV per internal count

System Linearity

Within 0.01% of full scale

Zero Stability

150 nV/°C, maximum

Span Stability

3.5 ppm/°C, maximum

Calibration Method

Software, constants stored in EEPROM

Common Mode

Voltage

–2.35 to +3.45 V, referred to ground

Rejection

130 dB minimum @ 50 or 60 Hz

Normal Mode

Rejection

90 dB minimum @ 50 or 60 Hz

Input Overload

± 12 V continuous, static discharge
protected

RFI Protection

Signal, excitation, and sense lines
protected by capacitor bypass

Serial Communications

Port 1

Full duplex RS-232

Port 2

Full duplex RS-232

Output only active 20 mA current loop

Port 3

Optional Ethernet, USB, or fiber optic
card

Operator Interface

Display

6-digit LED display. 14-segment, 0.8 in
(20 mm) digits

LED annunciators

Center of zero, gross, net, tare, preset
tare; percent, kg, g, lb, oz

Keypad

21-key flat membrane panel (CW-90)
Piezo membrane panel (CW-90X)

Environmental

Operating Temperature –10 to +40°C (legal);

–10 to +50°C (industrial)

Storage Temperature

–25 to +70°C

Humidity

0–95% relative humidity

Enclosure

Enclosure Dimensions 9.5 in x 6 in x 3.12 in

24 cm x 15 cm x 8 cm

Weight

2.8 Kg (6.1 lb)

Rating/Material

UL Type 4X

Certifications and Approvals

t

N

A

T

IO

NA

L CONFE

R

E

N

C

E

t

O
N

W

E

I G

H

T S

A N D M

E

A

S

U

R

E

S

CW-90/CW-90X Indicator

NTEP
CoC Number

08-092

Accuracy Class III/IIIL n

max

: 10 000

t

N

A

T

IO

NA

L CONFE

R

E

N

C

E

t

O
N

W

E

I G

H

T S

A N D M

E

A

S

U

R

E

S

CW-90/CW-90X Scale

NTEP
CoC Number

95-072A2

Accuracy Class III n

max

: 5 000

File Number

E151461-A7

Visit www.nsf.org and search by manufacturer.

Or visit the direct link at:

http://www.nsf.org/Certified/food/
Listings.asp?CompanyName=Rice+Lake%25&

Approval No. R76/2006-GB1-10.02
Accuracy Class II, III n

max

: 10 000

Measurement

Canada

Approved


Approval No. AM-5710

CAUTION

Do not use any parts on this scale that
may contain lead.

Advertising