Rice Lake Static Weighing User Manual

Page 36

Advertising
background image

32

CW-90/90X Checkweigher

BAUD

9600
19200
28800
38400
57600
115200
1200
2400
4800

Baud rate. Selects the transmission speed for the port.

BITS

8NONE
7EVEN
7ODD

Selects number of data bits and parity of data transmitted from the port.

STOP B

1
2

Stop bits. Sets the number of stop bits to 1 or 2.

TERMIN

CR/LF
CR

Termination character. Selects termination character for data sent from the port.

EOLDLY

000000

End-of-line delay. Sets the delay period, in 0.1-second intervals, from when a formatted
line is terminated to the beginning of the next formatted serial output. Value specified must
be in the range 0-255, in tenths of a second (10 = 1 second).

Note

An EOL may be required for continuous transmission at slower baud
rates to ensure the receiving buffer is empty before another string is
transmitted

ECHO

ON
OFF

This command enables or disables echoing of the serial commands sent to the indicator.

PRNMSG

ON
OFF

This parameter enables or disables the print message being displayed momentarily when
the unit receives a Print command.

Level 5 submenus

FUNCTN

OVER
UNDER
ACCEPT
ZEROBD

Sets the output to function when a value in the over, under, accept, or zero band is
reached.

TIMER

000000

Set the timer to 0 for output to remain on until the function state changes. Enter a value (in
20-millisecond increments, maximum 65535) to turn the digital output off after the
specified time (even though the function state has not changed).

TRIP

FRERUN
STABLE

FRERUN allows the output to toggle in motion;
STABLE waits for standstill.

SETUP Menu

Parameter

Choices

Description

Table 3-7. Serial, PFORMT, DIG I/O, VERS Submenu Parameters (Continued)