Rice Lake Static Weighing User Manual

Page 25

Advertising
background image

Configuration

21

Level 4 submenus

PRIMRY

UNITS
DECPNT
DSPDIV

Allows you to set the primary units, decimal point format, and display divisions.

SEC

KG
G
LB
OZ
LB/OZ*
OFF

Allows you to set the secondary units.

Decimal point format and display divisions are selected automatically. Values are
kg=kilogram (default); g=gram; lb=pound; oz=ounce; lb/oz=pound/ounce; and off.

Note

If using the <cu> token and secondary or tertiary values are changed, the
stream tokens must be changed to match in order to stream secondary
or tertiary.

*LB/OZ is not legal for trade. When in LB/OZ mode, the display shows a decimal
place for ounces through 99 pounds. If the pounds reach three digits (100 and
above), the ounces’ decimal place is dropped to accommodate the extra pounds’
digit.

99 15.9

Figure 3-6. LB/OZ mode display through 99 pounds

100

13

Figure 3-7. LB/OZ mode display for 100 pounds and above

TER

OFF
KG
G
LB
OZ
LB/OZ*

Allows you to set the tertiary units.

Decimal point format and display divisions are selected automatically. Values are off
(default); kg=kilogram; g=gram; lb=pound; oz=ounce; lb/oz=pound/ounce.

Important

Note

If using the <cu> token and secondary or tertiary values are changed, the
stream tokens must be changed to match in order to stream secondary
or tertiary.

*LB/OZ is not legal for trade. When in LB/OZ mode, the display shows a decimal
place for ounces through 99 pounds. If the pounds reach three digits (100 and
above), the ounces’ decimal place is dropped to accommodate the extra pounds’
digit (see Figure 3-6
and Figure 3-7).

If using a regulatory mode (see Section 9.6 on page 64), it is the installers responsibility to make sure
that the maximum allowable number of divisions is not exceeded by primary, secondary or tertiary
units of measure.

In this situation, the installer must reduce the number of divisions (also reducing the maximum
displayed capacity of the indicator) of the broader unit of measure to make sure that both units are
less than the allowed maximum per regulatory accreditation.

WZERO

Allows you to view or change the zero calibration a/d count value.

WVAL

Allows you to view and edit the test weight value.

Note

If RANGE is displayed after the value is entered, the value is too large or
small for the given parameter.

WSPAN

Allows you to view or change the span calibration a/d count value.

SCALE Menu

Parameter

Choices

Description

Table 3-4. Scale Menu Parameters (Continued)

Advertising
This manual is related to the following products: