1 value set: keyed, 2 value set: push, Value set: keyed – Rice Lake Static Weighing User Manual

Page 46: Value set: push

Advertising
background image

ACCEPT

UNDER

OVER

9.50

11.00

9.51-10.99

Under = 0.50 (.05%)
Over = 10.00 (10%)
Target = 10.00

42

CW-90/90X Checkweigher

Figure 5-4. Example of Under/Over/Target Settings in Target Weight Mode.

5.3.1

Value Set: Keyed

1. Press the

TARGET

key. The Accept light begins flashing and a flashing digit is shown.

2. Using the and keys to increment/decrement the values and the and keys to move between digits,

enter the desired value. If using the CW-90, you can also use the numeric keypad to enter the desired target
percent
value.

Note

Note

Note

To discard any changes and return to weigh mode, press the Menu button.

3. When the desired value is displayed, press

Enter

.

The decimal point flashes.

4. To change the position of the decimal point, use the and keys until it is in the desired position.

5. Press

Enter

again to accept the value and return to weigh mode.

6. Press the

OVER

key. The Over light begins flashing and a flashing digit is shown.

7. Using the and keys to increment/decrement the values and the and keys to move between digits,

enter the desired value, in percent (entering

10

equals

10%

). If using the CW-90, you can also use the

numeric keypad to enter the desired over value.

To discard any changes and return to weigh mode, press the Menu button.

8. When the desired value is displayed, press

Enter

.

The decimal point flashes.

9. To change the position of the decimal point, use the and keys until it is in the desired position.

10. Press

Enter

again to accept the value and return to weigh mode.

11. Press the

UNDER

key. The Under light begins flashing and a flashing digit is shown.

12. Using the and keys to increment/decrement the values and the and keys to move between digits,

enter the desired value, in percent (entering

5

equals

5%

). If using the CW-90, you can also use the numeric

keypad to enter the desired under value.

To discard any changes and return to weigh mode, press the Menu button.

13. When the desired value is displayed, press

Enter

.

The decimal point flashes.

14. To change the position of the decimal point, use the and keys until it is in the desired position.

15. Press

Enter

again to accept the value and return to weigh mode.

5.3.2

Value Set: Push

1. Place the weight you want to be used as the “target percent” value on the scale.

2. Press the

Enter

key. The Accept light flashes and the indicator displays

STORED

. The weight has been

captured and stored as the target percent value.

3. Press the

OVER

key. The Over light begins flashing and a flashing digit is shown.

4. Using the and keys to increment/decrement the values and the and keys to move between digits,

enter the desired value, in percent (entering

10

equals

10%

). If using the CW-90, you can also use the

numeric keypad to enter the desired over value.

Note

To discard any changes and return to weigh mode, press the Menu button.

Advertising