2 using a stored id, 3 weighvault, Using a stored id – Rice Lake Static Weighing User Manual

Page 49: Weighvault

Advertising
background image

Important

Note

Operation

45

29. When the desired description is displayed, press the

Enter

key to accept.

To discard any changes and return to weigh mode, press the Menu button.

30.

COPYWV

is displayed. This feature copies the current over/under/tare values, units, description 1 and

description 2 being used in normal weighing mode and saves them into the current ID number. If you do
not want to copy the working values into this ID, use the and keys to move to the next parameter.
Press
the

Enter

key to copy the current values into the ID. The indicator will display SAVING and return to

COPYWV when complete.

Do not select the following: COPYWV or CLEAR unless this is actually the function that you’re trying to
perform.

COPYWV copies the working values of Target, Over, Under, Tare, Units, Description 1 and 2 into the ID. It will erase all the
data that has been entered through the main menu.

CLEAR clears all values and descriptions in the ID.

31. When all parameters have been set, press the menu key to save the changes and return to weigh mode.

5.4.2

Using a Stored ID

1. Press the

ID

key. The last PROD ID being used is displayed with the left-most digit flashing.

2. Use the and keys to increment/decrement values and the and keys to move between digits until

the desired PROD ID value is displayed, or use the numeric keypad to enter the desired PROD ID.

Note

If an ID does not have values assigned, NO ID is displayed. The ZERO key acts as a backspace on the CW-90X.
Use this key to navigate from a two-digit ID to a one-digit ID. On the CW-90, use the CLR or ZERO key.

3. Press

Enter

to start using the PROD ID. “LOADING” is displayed, as well as the PROD ID number and

Description Field 1 (i.e., LOADING ID1 HAM). The indicator returns to weigh mode when the PROD ID
has been loaded.

5.4.3

WeighVault

WeighVault is a PC program which allows CW-90/CW-90X users to add, edit, and access IDs over a network
connection. WeighVault surpasses the CW-90/CW-90X's 50 ID limitation and eliminates front-panel entry of ID
parameters. It also collects data as transactions occur, and provides detailed transaction and productivity reports
which can be exported to Excel, Word, or PDF. For WeighVault to function, the following criteria must be met:

Ethernet card (wired or wireless) installed in the CW-90/CW-90X (Refer to PN72117 Ethernet TCP/IP
Interface Installation and Configuration Manual
or PN108680 WLAN Installation Instructions).

PC running the WeighVault service must have a static IP address

IP address assigned to the CW-90/CW-90X

WeighVault enabled in the CW-90/CW-90X menu (VAULT parameter; see Section 3.4.2 on page 23)

Port corresponding to the Ethernet card must be selected in the CW-90/90X menu (see Section 3.4.2 on
page 23)

Once the above criteria have been met, IDs can then be entered into WeighVault and saved on the PC’s hard drive.
The Edit Product dialog box in Figure 5-6 shows ID parameters which can be saved in WeighVault.

Figure 5-6. WeighVault Edit Product Dialog Box

Advertising