Serial Commands

49

6.1.2

ID Commands

Command

Function

ID.PRODID#N

(4 numeric digits max.)

ID.DESC1#N

(32 characters max.) (#N = ID number
referenced)

ID.DESC2#N

(32 characters max.)

ID.OVER#N

(weight value)

ID.UNDER#N

(weight value)

ID.TARE#N

(weight value)

ID.TARGET#N

(weight value)

ID.UNITS#N

(same in alternate units)

ID.SELECT#N

Selects a new ID

ID.CLEAR#N

Clears a single ID

ID.CLRALL

Clears all IDs (only if in menu mode)

ID.COPYWV#N

Copies working values to a specified
ID

ID.SELECT=XX

Loads IDXX into the working register. If
the ID is not found, the display will
show ??

ID.FINDPROD=XX

Returns the index where the ID is
found. If the ID is not found, the
display will show ??

Table 6-2. ID Commands

6.1.3

Reporting Commands

Reporting commands send specific information to the
serial port. The commands listed in Table 6-3 can be
used in all modes.

Table 6-3. Reporting Commands

Command

Function

DUMPALL

List all parameter values

DUMPAUDIT

List audit trail information

DUMPBUFFER

Lists buffer information

DUMPIDS

List all ID information

VERSION

Write CW-90/CW-90X software version

P

Write current displayed weight with units
identifier. See Section 9.3.2 on page 61.

ZZ

Write current weight and annunciator
status. See Section 9.3.2 on page 61.

XE

Returns a 10-digit code representing any
error conditions currently shown on the
front panel.

Note

Transmitting all configuration settings can be
achieved by the DUMPALL command or by
pressing PRINT while in menu mode.

6.1.4

Clear and Reset Commands

The following commands can be used to clear and reset
the CW-90/CW-90X:

RS

: Reset system. Resets the indicator without

resetting the configuration.

RESETCONFIGURATION

: Restores all configuration

parameters to their default values (menu mode
only). The

RESETCONFIGURATION

function can

also be initiated by pressing navigating to the

DEFALT

parameter under the VERS menu and

selecting YES. Then press

ENTER

to reset the

indicator.

Note

All load cell calibration settings are lost when
the RESETCONFIGURATION command is run.

CLEARBUFFER

: Clears the buffer information.

6.1.5

Parameter Setting Commands

Parameter setting commands allow you to display or
change the current value for a particular configuration
parameter (Tables 6-4 through 6-9).

Current configuration parameter settings can be
displayed in all modes using the following syntax:

command<ENTER>

Most parameter values can be changed in menu mode
only.

Use the following command syntax when changing
parameter values:

command=value<ENTER>

, where

value

is either a number or a parameter value. Use no

spaces before or after the equal (=) sign. If you type an
incorrect command, the display reads

??

.

For example, to set the motion band parameter to 5
divisions, type the following:

SC.MOTBAND=5<ENTER>

For parameters with selectable values, enter the
command and equal sign followed by a question mark:

command=?<ENTER>

to see a list of those values. The

indicator must be in menu mode to use this function.

Note

Some parameters are valid only if other
parameters or parameter values are specified.
Restrictions for front-panel configuration also
apply to serial command configuration.