Calibration Menu

See Section 4.0 on page 36 for calibration procedures. The Calibration menu can be protected by assigning a
password in the Feature menu.

Note

When entering a floating point value, the decimal point will appear and flash on the far right (if it is not already
on the screen). To move the decimal, press ENTER, then use the

and

keys to move the decimal to the

desired location.

The CW-90/CW-90X

requires the WZERO and WSPAN points to be calibrated. The linearity points are optional, but must

NOT duplicate zero or span. During calibration, the ENTER key acts as a data entry confirmation key. It also acts as an
EXECUTE key, and accepts the value if calibration was successful.

WZERO

Calibrating, please wait

Calibrating, please wait

Display and edi

Press Enter

to calibrate zero

t

test weight value

WVAL

WSPAN

Press Enter to

remove offset from

zero and span

calibrations

REZERO

WLIN

POINT–> 1

POINT–> 2

POINT–> 3

POINT–> 4

POINT–> 5

Same as POINT-> 1

WGT 1

number

Calibrating, please wait

Press Enter

to calibrate span

EXIT

T&D

TEST

SETUP

AUDIT

XXXXXXX

CALIBR

BRIGHT

Press Menu

to cancel

Press Menu

to cancel

Previous A/D raw

counts are shown

Previous A/D raw

counts are shown

ACCUM

Only displayed if

turned on

from Setup menu

CAL1

ID

Only displayed if

turned on

from Setup menu

Figure 3-4. Calibration Menu

CALIBR Menu

Parameter

Choices

Description

Level 2 submenus

WZERO

Press ENTER and the A/D raw counts will be displayed.

Press ENTER again to calibrate zero, or press MENU to cancel. “CALIBRATING, PLEASE
WAIT” will be appear prior to automatically moving to WVAL.

WVAL

Press ENTER to display and edit the test weight value. Press ENTER again to move to
WSPAN.

WSPAN

Press ENTER and the A/D raw counts will be displayed. Press ENTER to calibrate the span or
press MENU to cancel. “CALIBRATING, PLEASE WAIT” will be appear prior to automatically
moving to WLIN.

WLIN

PT->1 — PT->5

WGT 1 allows you to display and edit the test weight value. Press ENTER to edit the value.

CAL1 allows you to calibrate and display the raw A/D value. Press TARE to perform
calibration. Press ENTER to will move to the next calibration point.

Note

The linearity points are optional, but must NOT duplicate zero or span. They
must be between zero and span.

REZERO

Press ENTER to remove an offset value from the zero and span calibrations (e.g. if hooks or
chains are being used during calibration).

Note

Use this parameter only after WZERO and WSPAN have been set. See
Section 4.1 on page 36
for more information about using this parameter.