Operation

41

8. When the desired value is displayed, press

Enter

.The decimal point flashes.

9. To change the position of the decimal point, use the and keys until it is in the desired position.

10. Press

Enter

again to accept the value and return to weigh mode.

11. Press the

UNDER

key. The Under light begins flashing and a flashing digit is shown.

12. Using the and keys to increment/decrement the values and the and keys to move between digits,

enter the desired value. If using the CW-90, you can also use the numeric keypad to enter the desired under
value.

To discard any changes and return to weigh mode, press the Menu button.

13. When the desired value is displayed, press

Enter

.

The decimal point flashes.

14. To change the position of the decimal point, use the and keys until it is in the desired position.

15. Press

Enter

again to accept the value and return to weigh mode.

5.2.2

Value Set: Push

1. Place the weight you want to be used as the “target” on the scale.

2. Press the

Target

key. The Accept light flashes and the indicator displays

STORED

. The weight has been

captured and stored as the target weight.

3. Press the

OVER

key. The Over light begins flashing and a flashing digit is shown.

4. Using the and keys to increment/decrement the values and the and keys to move between digits,

enter the desired value. If using the CW-90, you can also use the numeric keypad to enter the desired over
value.

Note

Note

To discard any changes and return to weigh mode, press the Menu button.

5. When the desired value is displayed, press

Enter

.

The decimal point flashes.

6. To change the position of the decimal point, use the and keys until it is in the desired position.

7. Press

Enter

again to accept the value and return to weigh mode.

8. Press the

UNDER

key. The Under light begins flashing and a flashing digit is shown.

9. Using the and keys to increment/decrement the values and the and keys to move between digits,

enter the desired value. If using the CW-90, you can also use the numeric keypad to enter the desired under
value.

To discard any changes and return to weigh mode, press the Menu button.

10. When the desired value is displayed, press

Enter

. The decimal point flashes.

11. To change the position of the decimal point, use the and keys until it is in the desired position.

12. Press

Enter

again to accept the value and return to weigh mode.

5.3

Target Percent Mode

In

Target Percent

mode, the over and under values can only be set by keying in the values (in percentages). The

VALSET parameter only pertains to setting the target weight value. The Accept band is determined based on a
percentage of the desired target weight.

Note

The % annunciator will be lit during target percent setup in menu mode, but not in weigh mode.