2.3

Zero Parameters

1. Press and hold

, then press

to enter set-up menu, CALIb will be displayed.

2. Press

or

until  is displayed, press

.

3. Press

or

until desired parameter (see Table 5 ) is displayed, press

. The currently programmed

value is displayed.

4. Press

or

until desired value is displayed, press

.

5. Press

twice to exit set-up menu.

2.4

SCT20-DN (DeviceNet) Settings

1. Press and hold

and

to enter set-up menu. CALIb will be displayed.

2. Press

or

until dEUnEt is displayed, press

.

3. Press

or

until desired parameter is displayed, press

.

4. Press

or

until desired value is displayed, press

.

5. Press

twice to exit set-up menu.

Parameter

Choices

Description

0 SEt

Enter #
0-max full scale

300 *

Considered decimals:
300 – 30.0 – 3.00 –
0.300

Maximum zero range
Indicates the maximum weight value that can be zeroed off by external contact,
keypad or serial protocol

AutO 0

Enter #
0 - max 20% of full scale

0 *

Automatically zeroes the scale at power-on
If the weight value is lower than the value set in this parameter, the scale will zero
itself provided the weight does not exceed the value in the 0 SET parameter. To
disable this function set to 0.

trAC 0

nOnE *

1

-5

Zero tracking
Automatically zeroes the scale when within the range specified, as long as the
weight is within the 0 SET parameter and the scale is at standstill for at least one
second.
To disable this function

,

set to none

Example: if the parameter dI UI S is set to 5 and trAC 0 is set to 2, the weight
will be automatically set to zero for variations smaller than or equal to 10 (
dI

UI S x trAC 0 ).

* - indicates default value.

Parameter

Choices

Description

Addr

1

-63

1 *

Set instrument address in the DeviceNet network.

bAud

6125H
6250H
6500H *

Set instrument address in the DeviceNet network.

* - indicates default value.