Digital outputs status digital outputs command, Status register – Rice Lake Signal Conditioning Transmitter/Indicators User Manual

Page 47

Advertising
background image

Operation 43

Digital Outputs Status

Digital Outputs Command

It allows control to the outputs status in EtHnEt mode (see Section 2.10 on page 27)

Bit a 1: output is closed; Bit a 0: output is open.

Setting bit 15 to 1 on the PLC, DeviceNet takes control of all the outputs, even if they are in different modes.

Status Register

Bit 0

OUTPUT 1 status

Bit 4

Bit 1

OUTPUT 2 status

Bit 5

Bit 2

OUTPUT 3 status

Bit 6

Bit 3

Bit 7

Bit 0

OUTPUT 1 status

Bit 8

Bit 1

OUTPUT 2 status

Bit 9

Bit 2

OUTPUT 3 status

Bit 10

Bit 3

Bit 11

Bit 4

Bit 12

Bit 5

Bit 13

Bit 6

Bit 14

Bit 7

Bit 15

Force Outputs

Bit 0

Cell Error

Bit 1

A/D Converter Malfunction

Bit 2

Maximum weight exceeded by 9 divisions

Bit 3

Gross weight higher than 110% of full scale

Bit 4

Gross weight beyond 999999 or less than -999999

Bit 5

Net weight beyond 999999 or less than -999999

Bit 6

Bit 7

Gross weight negative sign

Bit 8

Net weight negative sign

Bit 9

Peak weight negative sign

Bit 10

Net display mode

Bit 11

Weight stability

Bit 12

Weight within +/-¼ of a division around ZERO

Bit 13

Bit 14

Bit 15

Note