Rice Lake Signal Conditioning Transmitter/Indicators User Manual

Page 55

Advertising
background image

Operation 51

Divisions And Units Measure Registry (40014)

This register contains the current setting of the divisions (parameter dI UI S) and of the units of measure (UnIt
parameter).

Use this register together with the Coefficient registers to calculate the value displayed by the instrument.

H Byte

L Byte

Units of measure

division

Least significant byte

(L Byte)

Most significant byte

(H Byte)

Division

value Divisor

Decimals

Units of measure

value

Units of measure

description

Utilization of the Coefficient value with

the different units of measure settings

compared to the gross weight detected

0

100

0

0

Kilograms

Does not intervene

1

50

0

1

Grams

Does not intervene

2

20

0

2

Tons

Does not intervene

3

10

0

3

Pounds

Does not intervene

4

5

0

4

Newton

Multiples

5

2

0

5

Litres

Divides

6

1

0

6

Bar Multiples

7

0.5

1

7

Atmspheres

Multiples

8

0.2

1

8

Pieces Divides

9

0.1

1

9

Newton Meter

Multiples

10

0.05

2

10

Kilogram Meter

Multiples

11

0.02

2

11

Other Multiples

12 0.01

2

13

0.005

3

14

0.002

3

15

0.001

3

16

0.0005

4

17

0.0002

4

18

0.0001

4

Advertising
This manual is related to the following products: