36 SCT Weight Transmitter Operator’s Manual

Digital Outputs Status

Digital Outputs Command

It allows to control the outputs status in dEUnEt mode (see Section 2.10 on page 27)

Bit a 1: output is closed; Bit a 0: output is open.

Setting bit 15 to 1 on the PLC, DeviceNet takes control of all the outputs, even if they are in different modes.

Status Register

3.7

Profibus

• The instrument works as a Profibus DP V0 slave in a Profibus DP network.
• Load the included gsd file (LAU_0C91.gsd) attached to the instrument in the development system of the

Profibus master.

• The available modules are:

- R = the register can be read only
- W = the register can be written only
- R/W = the register can be both read and written

Bit 0

OUTPUT 1 status

Bit 4

Bit 1

OUTPUT 2 status

Bit 5

Bit 2

OUTPUT 3 status

Bit 6

Bit 3

Bit 7

Bit 0

OUTPUT 1 status

Bit 8

Bit 1

OUTPUT 2 status

Bit 9

Bit 2

OUTPUT 3 status

Bit 10

Bit 3

Bit 11

Bit 4

Bit 12

Bit 5

Bit 13

Bit 6

Bit 14

Bit 7

Bit 15

Force Outputs

Bit 0

Cell Error

Bit 1

A/D Converter Malfunction

Bit 2

Maximum weight exceeded by 9 divisions

Bit 3

Gross weight higher than 110% of full scale

Bit 4

Gross weight beyond 999999 or less than -999999

Bit 5

Net weight beyond 999999 or less than -999999

Bit 6

Bit 7

Gross weight negative sign

Bit 8

Net weight negative sign

Bit 9

Peak weight negative sign

Bit 10

Net display mode

Bit 11

Weight stability

Bit 12

Weight within +/-¼ of a division around ZERO

Bit 13

Bit 14

Bit 15

Note