Operation 41

To verify the correct execution of the calibration command:

• Write the sample weight value to the “Sample Weight for calibration” module;
• Write the value 0 to the “”Sample Weight for calibration” module;
• Send the command 101 “Sample weight storage for calibration” to the Command Register;
• The operation works correctly if the module value “Sample Weight for calibration” goes to zero.

Changing some instrument parameters via keyboard can take the Profibus network out of the data exchange
status and put the PLC in stop status; when programming the instrument the plant must be in stand-by status

3.8

SCT20-IP (EtherNet/IP)

The instrument works as a device in a Ethernet/IP network.
Load the included eds file (TLBEIP.eds) in the Ethernet/IP scanner’s development instrument. Or you can open

Class 1 I/O Connection with the following settings:

• Assembly Instance = 101; Size = 10
• Assembly Instance = 102; Size = 5
• Assembly Instance = 128; Size = 0

The data exchanged by SCT20-IP are:

Outgoing Data from SCT20-IP (Read)

Addresses

Internal Status [2 bytes]

0x0000-0x0001

Gross Weight [4 bytes]

0x0002-0x0005

Net Weight [4bytes]

0x0006-0x0009

Setpoint [4 bytes]

0x000A-0x000D

Status Register [2 bytes]

0x000E-0x000F

Digital Inputs Status [2 byte]

0x0010-0x0011

Digital Outputs Status [2 byte]

0x0012-0x0013

Input Data to SCT20-IP (Write)

Addresses

Write Enable [2 bytes]

0x0000-0x0001

Command Register [2 bytes]

0x0002-0x0003

Digital Outputs Command [2bytes]

0x0004-0x0005

Setpoint [4 bytes]

0x0006-0x0009

Note

EtherNet/IP