40 SCT Weight Transmitter Operator’s Manual

Status Register

Bit 13 (writing error) rises if the PLC tries to write a value out of a parameter’s permitted interval. In this case the

writing has no effect and the previous parameter value is maintained.

Possible Command To Send To The Command Register

Commands are sent only once; to reassert it write the value 0 to the Command register and then the command
again

Real Calibration Commands (With Sample Weight)

The instrument calibration can be changed via PROFIBUS.
To correctly set the sample weight, consider the value of the division module (e); e.g. if you want to set the value to

100kg and the division value is 0.001, set the register value to 100000 (you remove the decimal points form the

value that would be 100.000 with decimals).
To perform the edit calibration procedure, it needs to unload the system and zero-setting the displayed weight value

with the command 100 “Zero-setting for calibration” of Command Register. Then, put a sample weight onto the

system, write the correct known weight value to the “Sample Weight for calibration” register; to save in memory

the sample weight value, send the command 101 “Sample weight storage for calibration”.

Bit 0

Cell Error

Bit 1

A/D Converter Malfunction

Bit 2

Maximum weight exceeded by 9 divisions

Bit 3

Gross weight higher than 110% of full scale

Bit 4

Gross weight beyond 999999 or less than -999999

Bit 5

Net weight beyond 999999 or less than -999999

Bit 6

Bit 7

Gross weight negative sign

Bit 8

Net weight negative sign

Bit 9

Peak weight negative sign

Bit 10

Net display mode

Bit 11

Weight stability

Bit 12

Weight within +/-¼ of a division around ZERO

Bit 13

Writing error

Bit 14

Bit 15

0

No command

17

Reserved

7

NET display

18

Reserved

8

SEMI-AUTOMATIC ZERO

21

Keypad lock

10

Reserved

22

Keypad and display unlock

11

Reserved

23

Keypad and display lock

12

Reserved

99

Save data in EEPROM

13

Reserved

100

Zero-setting for calibration

14

Reserved

101

Sample weight storage for
calibration

15

Reserved

9999

Reset (reserved)

16

Reserved

Note