54 SCT Weight Transmitter Operator’s Manual

in which:

s = 1 separator character (32 ASCII – space-).

Generally refer Section 3.5 “Alarms” on page 34.

Semi-Automatic Zero (Weight Zero-Setting For Small Variations)

The zero-setting will not be maintained after an instrument power-off.

The PC transmits: $aaZEROckckCR

$01ZERO03CR

Possible instrument responses:

- correct reception: &&aa!\ckckCR
- incorrect reception: &&aa?\ckckCR
- the current weight is over the maximum value resettable: &aa#CR

Switching From Gross Weight To Net Weight

The PC transmits: $aaNETckckCR

$01NET5ECR

Possible instrument responses:

- correct reception: &&aa!\ckckCR
- incorrect reception: &&aa?\ckckCR

Switching From Net Weight To Gross Weight

The PC transmits: $aaGROSSckckCR

$01GROSS5BCR

Possible instrument responses:

- correct reception: &&aa!\ckckCR
- incorrect reception: &&aa?\ckckCR

Reading Of Decimals And Number Of Divisions

The PC transmits: $aaDckckCR

$01D45CR

Possible instrument responses:

- correct reception: &aaxy\ckckCR
- incorrect reception: &&aa?\ckckCR

in which:

x = number of decimals

y = division value

The y field acquires the following values:

'3' for division value = 1;
'4' for division value = 2;
'5' for division value = 5;
'6' for division value = 10;
'7' for division value = 20;
'8' for division value = 50;
'9' for division value = 100;

Important