Operation 39
Digital Inputs Status
Bit a 1: input high; Bit a 0: input is low
Digital Outputs Command
It allows control to the outputs status in PrOFI (see Section 2.10 on page 27)
Bit a 1: output is closed; Bit a 0: output is open.
Setting bit 15 to 1 on the PLC, Profibus takes control of all the outputs, even if they are in different modes.
Bit 0
INPUT 1 status
Bit 8
Bit 1
INPUT 2 status
Bit 9
Bit 2
Bit 10
Bit 3
Bit 11
Bit 4
Bit 12
Bit 5
Bit 13
Bit 6
Bit 14
Bit 7
Bit 15
Bit 0
OUTPUT 1 status
Bit 8
Bit 1
OUTPUT 2 status
Bit 9
Bit 2
OUTPUT 3 status
Bit 10
Bit 3
Bit 11
Bit 4
Bit 12
Bit 5
Bit 13
Bit 6
Bit 14
Bit 7
Bit 15
Force Outputs