Coefficient display – Rice Lake Signal Conditioning Transmitter/Indicators User Manual

Page 42

Advertising
background image

38 SCT Weight Transmitter Operator’s Manual

Coefficient Display

The Profibus register contains the value of parameter COEFF, expressed as integer number, with 4 decimal figures

but without decimal point.
E.g.: If COEFF is 1.2000, the Profibus register contains 12000

Least significant byte

(L Byte)

Most significant byte

(H Byte)

Division

value Divisor

Decimals

Units of

measure

value

Units of

measure

description

Utilization of the Coefficient

value with the different units of

measure settings compared to

the gross weight detected

0

100

0

0

Kilograms Does

not

intervene

1

50

0

1

Grams Does

not

intervene

2

20

0

2

Tons Does

not

intervene

3

10

0

3

Pounds Does

not

intervene

4

5

0

4

Newton

Multiples

5

2

0

5

Litres

Divides

6

1

0

6

Bar Multiples

7

0.5

1

7

Atmsphere
s

Multiples

8

0.2

1

8

Pieces Divides

9

0.1

1

9

Newton
Meter

Multiples

10

0.05

2

10

Kilogram
Meter

Multiples

11

0.02

2

11

Other Multiples

12 0.01

2

13

0.005

3

14

0.002

3

15

0.001

3

16

0.0005

4

17

0.0002

4

18

0.0001

4

Advertising