6. RS-485 communication I/O (RS-485 COMM. I/O)

The protocol for communicating with other equipment by RS-485 can be set here.

Q]: Switched with rotary encoder “1”.

OFF;

No transmission or reception is possible.

PGM CHANGE: Only program change can be transmitted and all the data can be received. (BULK OUT is

possible)

ALL:

All the data (program change and parameter set value) is transmitted and received.