Echelon FT 3150 Smart Transceiver User Manual

Page 105

Advertising
background image

FT 3120 / FT 3150 Smart Transceiver Data Book

99

EMI Design Issues

Careful PCB layout is important to ensure that a FT Smart Transceiver based-device will achieve the desired level
of EMC. A typical FT Smart Transceiver based-device will have several digital signals switching in the 1-40MHz
range. These signals will generate voltage noise near the signal traces, and will also generate current noise in the
signal traces and power supply traces. The goal of good device design is to keep this voltage and current noise from
coupling out of the product's package.

It is very important to minimize the leakage capacitance from circuit traces in the device to any external pieces of
metal near the device, because this capacitance provides a path for the digital noise to couple out of the product's
package. Figure 4.5 shows the leakage capacitances to earth ground from a device's logic ground (C

leak,GND

) and

from a digital signal line in the device (C

leak,SIGNAL

). If the FT Smart Transceiver based-device is housed inside of

a metal chassis, then that metal chassis will probably have the largest leakage capacitance to other nearby pieces of
metal. If the device is housed inside of a plastic package, then PCB ground guarding must be used to minimize
C

leak,SIGNAL

. Effective guarding of digital traces with logic ground reduces C

leak,SIGNAL

significantly, which reduces

the level of common-mode RF currents driven onto the network cable.

Figure 4.5 Parasitic Leakage Capacitances to Earth Ground

When a device is mounted near a piece of metal, especially metal that is earth grounded, any leakage capacitance
from fast signal lines to that external metal will provide a path for RF currents to flow. When V

gate

is pulled down

to logic ground, the voltage of logic ground with respect to earth ground will increase slightly. When V

gate

pulls up

to V

CC

, logic ground will be pushed down slightly with respect to earth ground. As C

leak,SIGNAL

increases, a larger

Twisted

Pair

Network

Leakage

Capacitances to

Earth Ground

C

leak,GND

C

load

Smart Transciever

V

cc

Node

Logic

Ground

Floating Device on TP/FT-10 Network

C

decouple

C

leak,SIGNAL

V

gate

NET_A

NET_B

Vcc

GND

CHASSIS

GND

C

leak,CHASSIS

Advertising
This manual is related to the following products: