FT 3120 / FT 3150 Smart Transceiver Data Book

79

Timer/Counter Input Objects

A call to this function returns the current value of the quadrature count since the last read operation. The counter is
then reset and ready for the next series of input transitions. The count returned is a 16-bit signed binary number,
capped at ±16K.

The number shown in the diagram above is the minimum time allowed between consecutive transitions at either input
of the quadrature function block. For more information, see the, Neuron Chip Quadrature Input Function Interface
engineering bulletin.

Totalcount Input

A timer/counter may be configured to count either rising or falling input edges, but not both. Reading the value of a
totalcount object gives the number of transitions since the last time it was read (0 to 65,535). Maximum frequency of
the input is one-quarter of the input clock rate, for example 2.5MHz at a maximum of 10MHz FT Smart Transceiver
input clock. This object is useful for counting external events such as contact closures, where it is important to keep
an accurate running total. See Figure 3.43.

Figure 3.43 Totalcount Input Latency Values

Symbol

Description

Typ @ 10MHz

t

fin

Function call to input sample

92 µs

t

ret

Return from function

61 µs

read input_value = 4, reset

read, reset

t

ret

t

fin

READ

TIMER/

COUNTER
FLAG AND

EVENT REGISTER

CLEAR FLAG

END OF

io_in()

START OF

io_in()

Event Register

Event Register

Timer/Counter 1

Timer/Counter 2

mux

IO10

IO9

IO8

IO0
IO1
IO2
IO3

IO4
IO5

IO6
IO7

Reference Figure 3.35

Optional Pull-Up Resistors