Notes, N , notes, Section , notes . the – Echelon FT 3150 Smart Transceiver User Manual

Page 94

Advertising
background image

Chapter 3 - Input/Output Interfaces

88

FT 3120 / FT 3150 Smart Transceiver Data Book

Figure 3.50 Triggered Count Output Latency Values

The active output level depends on whether or not the invert option was used in the declaration of the function block.
The default is high.

Notes

Various combinations of I/O pins may be configured as basic inputs or outputs. The application program may
optionally specify the initial values of basic outputs. Pins configured as outputs may also be read as inputs, returning
the value last written.

Symbol

Description

Typ @ 10MHz

t

fout

Function call to output pulse

109 µs

t

cod

Last negative sync
Clock edge to output inactive

min 550 ns
max 750 ns

t

ret

Return from function

7 µs

END OF

io_out()

OUTPUT

INACTIVE

LAST ACTIVE

SYNC CLOCK

EDGE

OUTPUT

ACTIVE

START OF

io_out()

t

ret

t

cod

t

fout

TIME

SYNC

INPUT

OUTPUT

Control Output

IO10

IO9

IO8

IO0
IO1
IO2
IO3
IO4
IO5
IO6
IO7

Timer/Counter 1

Timer/Counter 2

Count Input

mux

High Current Sink Drivers

Optional Pull-Up Resistors

Advertising