This appendix includes a checklist to ensure that FT Smart Transceivers-based devices meet all the specifications
presented in this user guide.

Device Checklist

Table A.1 FT Smart Transceiver Connections

Item

Check When
Completed

Description

1

FT-X1 transformer pins connected as shown in the FT 3120 / FT 3150 Smart
Transceiver Datasheet
and in Figure 4.1.

2

Environmental and electrical specifications as shown in the FT 3120 / FT
3150 Smart Transceiver Datasheet
.

3

For FT-X1 designs, ESD protection diodes are connected to pins 5 and 6 of
the FT-X1 transformers.

4

Pin T2 from the FT Smart Transceiver is connected to pin 4 on the FT-X1
transformer. For FT-X2 designs, the layout connection is not routed under-
neath the old pin traces (pins 3 and 4) of FT-X1 (see “FT 3150 Evaluation
Board Composite Top Layer” on page 145).

5

The recommended number and placement of 0.1µF bypass capacitors are
near the FT Smart Transceiver.

6

The FT Smart Transceiver input clock frequency is 5MHz, 10MHz, 20MHz,
or 40MHz and accurate to ± 200 ppm. The input clock frequency of 40MHz is
valid for the FT 3120 Smart Transceiver only.

7

The FT Smart Transceiver and FT-X1 or FT-X2 Communications Transformer
are placed adjacent to one another on the same printed circuit board.

8

If required, a low voltage interrupt (LVI) circuit with open collector output is
used to supply a reset signal to the FT Smart Transceiver.

9

Clamping diodes and 470V MOV are used in the ESD protection circuit
shown in Figure 4.1.