Ven by table 3.7, Table 3.8, Ut, table 3.7 giv – Echelon FT 3150 Smart Transceiver User Manual

Page 96

Advertising
background image

Chapter 3 - Input/Output Interfaces

90

FT 3120 / FT 3150 Smart Transceiver Data Book

Table 3.7 Timer/Counter Square Wave Output

This table is for 10MHz input clock. Scale appropriately for other clock rates:

Period (µs) = 512 x 2

Clock Select

/ (Input Clock in MHz)

Frequency (Hz) = 1,000,000 / Period (µs).

For 20MHz and 40MHz operation, the numbers should be scaled accordingly.

For pulsewidth long output, Table 3.8 gives the possible choices for pulsetrain repetition frequencies.

Table 3.8 Timer/Counter Pulsetrain Output

This table is for 10MHz input clock. Scale appropriately for other clock rates:

Period (ms) = 131.072 x 2

Clock Select

/ (Input Clock in MHz)

Frequency (Hz) = 1,000 / Period (ms)

As with all CMOS devices, floating I/O pins can cause excessive current consumption. To avoid this, declare all
unused I/O pins as bit output. Alternatively, unused I/O pins may be connected to + V

DD

or GND.

Clock Select

(System Clock

÷)

Repetition Rate

(Hz)

Repetition
Period

(µs)

Resolution
of Pulse

(µs)

0 (

÷1) (5MHz)

19,531

51.2

0.2

1 (

÷ 2) (2.5MHz)

9,766

102.4

0.4

2 (

÷ 4) (1.25MHz)

4,883

204.8

0.8

3 (

÷ 8) (625 kHz)

2,441

409.6

1.6

4 (

÷ 16) (312.5 kHz)

1,221

819.2

3.2

5 (

÷ 32) (156.25 kHz)

610

1,638.4

6.4

6 (

÷ 64) (78.125 kHz)

305

3,276.8

12.8

7 (

÷ 128) (39.06 kHz)

153

6,553.6

25.6

Clock Select

Frequency
(Hz)

Period
(ms)

0

76.3

13.1

1

38.1

26.2

2

19.1

52.4

3

9.54

105

4

4.77

210

5

2.38

419

6

1.19

839

7

0.60

1,678