Magcard input, Figure 3.25 i, C i/o object – Echelon FT 3150 Smart Transceiver User Manual

Page 66

Advertising
background image

Chapter 3 - Input/Output Interfaces

60

FT 3120 / FT 3150 Smart Transceiver Data Book

Figure 3.25 I

2

C I/O Object

Magcard Input

This I/O object is used to transfer synchronous serial data from an ISO 7811 Track 2 magnetic stripe card reader in
real time. The data is presented as a data signal input on pin IO9, and a clock, or a data strobe, signal input on pin IO8.
The data on pin IO9 is clocked on or just following the falling (negative) edge of the clock signal on IO8, with the

Parameter

Description

Min

Typ

Max

t

f

I/O call to start condition
io_in()
io_out()


54.6 µs
43.4 µs


t

start

End of start condition
io_in()
io_out()

5.4 µs
5.4 µs



t

cla

End of start to start of address
io_in()
io_out()

24.0 µs
24.0 µs



t

cld

SCL low to data for io_out()

24.6 µs

t

dch

Data to SCL high for io_out()

7.2 µs

t

chcl

Clock high to clock low for io_out()

12.6 µs

t

chd

SCL high to data sampling for io_in()

13.2 µs

t

dcl

Data sample to SCL low for io_in()

7.2 µs

t

clch

Clock low to clock high for io_in()

24.0 µs

t

stop

Clock high to data
io_in()
io_out()

12.6 µs
12.6 µs



t

ret

SDA high to return from function
io_in()
io_out()



4.2 µs
4.2 µs

IO10

IO9

IO8

IO0

IO1

IO2

IO3

IO4

IO5

IO6

IO7

t

dch

SCL

SDA

TIME

START OF

io_in() OR

io_out()

INPUT DATA

SAMPLED

t

chcl

t

cld

t

chd

t

dcl

t

clch

SCL

SDA

TIME

t

stop

t

ret

t

f

t

start

t

cla

END OF

io_in() OR

io_out()

BIT TRANSFER TIMING

START AND STOP TIMING