Magtrack1 input – Echelon FT 3150 Smart Transceiver User Manual

Page 68

Advertising
background image

Chapter 3 - Input/Output Interfaces

62

FT 3120 / FT 3150 Smart Transceiver Data Book

Magtrack1 Input

This input object type is used to read synchronous serial data from an ISO3554 magnetic stripe card reader. The data
input is on pin IO9, and the clock, or data strobe, is presented as input on pin IO8. The data on pin IO9 is clocked in
just following the falling edge of the clock signal on IO7, with the LSB first.

Figure 3.27 Magtrack1 Input Object

The minimum period for the entire bit cycle (t

clk

) is greater than the sum of t

low

and t

high

. The t

setup

and t

hold

times should be such that the data is stable for the duration of t

low

.

Symbol

Description

Min

Typ

Max

t

fin

Function call to first clock input

45.0 µs

t

hold

Data hold

t

low

t

clk

t

setup

Data setup

0 µs

t

low

Clock low width

31 µs

t

high

Clock high width

31 µs

t

wto

Width of timeout pulse

60 µs

t

clk

Clock period

138 µs

t

tret

Return from timeout

21.6 µs

81.6 µs

t

ret

Return from function

301.8 µs

Serial Data

Clock

IO10

IO9

IO8

IO0

IO1

IO2

IO3

IO4

IO5

IO6

IO7

Timeout

t

wto

CLOCK

(IO8)

SDA

(IO9)

TIMEOUT

START OF

io_in()

t

hold

END OF

io_in()

t

setup

t

high

t

ret

t

fin

TIME

t

low

t

tret

t

clk

Advertising