Period input, And 3.39 – Echelon FT 3150 Smart Transceiver User Manual

Page 81

Advertising
background image

FT 3120 / FT 3150 Smart Transceiver Data Book

75

Timer/Counter Input Objects

*If the measurement is new, t

ret

= 52 µs. If a new time is not being returned, t

ret

= 22 µs.

Figure 3.39 Ontime Latency Values

This is a level-sensitive function. The active level of the input signal gates the clock driving the internal counter in the
FT Smart Transceiver.

The actual active level of the input depends on whether or not the invert option was used in the declaration of the
function block. The default is the high level.

Period Input

A timer/counter may be configured to measure the period from one rising or falling edge to the next corresponding
edge on the input. Table 3.6 shows the resolution and maximum time measured for various clock selections. This
object is useful for instantaneous frequency or tachometer applications. Analog-to-digital conversion can be
implemented using a voltage-to-frequency converter with this object. See Figure 3.40.

Symbol

Description

Typ @ 10MHz

t

fin

Function call to input sample

86 µs

t

ret

Return from function

52/22 µs*

mux

Event Register

IO10

IO9

IO8

IO0
IO1
IO2
IO3

IO4
IO5

IO6
IO7

System Clock

Divide Chain

Optional Pull-Up Resistors

Reference Figure 3.35

Event Register

Timer/Counter 2

Timer/Counter 1