Figure 18-1: ALTERA_FP_FUNCTIONS Signals

clk

b (1), (2)

ALTERA_FP_FUNCTIONS

q

(1)

a (1)

areset

1) The floating point and fixed point data widths determine the port width of this port.
2) This port is not relevant for convert and square root functions.

Table 18-6: ALTERA_FP_FUNCTIONS Input Signals

Port Name

Required

Description

clk

Yes

All input signals must be synchronous to this clock.

areset

Yes

Asynchronous active-high reset. Deassert this signal synchronously to

the input clock to avoid metastability issues.

en

No

Global enable signal. This signal is optional.

a

Yes

Data input signal.

b

Yes

Data input signal (where applicable).

s

Yes

Select port for Add/Sub function.

c

Yes

Data port for integer exponent port for LDExp function.

Table 18-7: ALTERA_FP_FUNCTIONS Output Signals

Port Name

Required

Description

q

Yes

Data output signal.