Altera Floating-Point User Manual

Page 86

Advertising
background image

Parameter Name

Type

Required

Description

WIDTH_MAN

Integer

Yes

Specifies the value of the mantissa. If this parameter

is not specified, the default is

23

. When the

WIDTH_

EXP

parameter is

8

and the floating-point format is

single-precision, the

WIDTH_MAN

parameter value

must be

23

. Otherwise, the value of the

WIDTH_MAN

parameter must be a minimum of

31

. The value of

the

WIDTH_MAN

parameter must be greater than the

value of the

WIDTH_EXP

parameter. The sum of the

WIDTH_EXP

and

WIDTH_MAN

parameters must be less

than

64

.

PIPELINE

Integer

Yes

Specifies the amount of latency in clock cycles used

in the ALTFP_INV megafunction. Create the

ALTFP_INV megafunction with the MegaWizard

Plug-In Manager to calculate the value for this

parameter.

ROUNDING

String

No

Specifies the rounding mode. The default value is

TO_NEAREST

. Other rounding modes are not

supported.

10-6

Parameters

UG-01058

2014.12.19

Altera Corporation

ALTFP_INV IP Core

Send Feedback

Advertising