Altera Floating-Point User Manual

Page 154

Advertising
background image

Category

Parameter

Values

Descriptions

Fixed Point Data

Width

16 to 128

The bit width of the fixed

point data port. This

parameter is only available

when the Name parameter is

set to Convert.

Fraction

0 to Fixed Point Data

Width

The bit width of the fraction.

This parameter is only

available when the Name

parameter is set to Convert.

Sign

Signed, Unsigned

Chose if the fixed point data

is signed or unsigned. This

parameter is only available

when the Name parameter is

set to Convert. The default

value is signed.

Rounding

Mode

• nearest with tie

breaking to even

• toward zero

• nearest with tie

breaking away

from zero

The rounding mode. The

nearest with tie breaking

away from zero and toward

zero values are only available

when you use arithmetic

functions

Relax rounding to

round up or down to

reduce resource

usage

Turn on, Turn Off

Choose if the nearest

rounding mode should be

relaxed to faithful rounding,

where the result may be

rounded up or down, to

reduce resource usage. Only

available for arithmetic

functions

Ports

Generate Enable

Port

Turn on, Turn Off

Choose if the ALTERA_FP_

FUNCTION IP core should

have an enable signal.

UG-01058

2014.12.19

ALTERA_FP_FUNCTIONS Parameters

18-27

ALTERA_FP_FUNCTIONS IP Core

Altera Corporation

Send Feedback

Advertising