background image

Chapter 5: Signals

5–9

Out-of-Band Flow Control Interface Signals

June 2012

Altera Corporation

Interlaken MegaCore Function

User Guide

rx_oob_in_fc_data

Input

Input serial data pin from an upstream out-of-band TX block. You
must connect this signal to a device pin.

rx_oob_in_fc_sync

Input

Input sync control pin from an upstream out-of-band TX block. You
must connect this signal to a device pin.

Note to

Table 5–9

:

(1) The maximum rx_oob_in_clk frequency allowed by the Interlaken specification is 100 MHz. Altera recommends that you run the

rx_oob_in_clk

clock at 100 MHz.

Table 5–9. RX Out-of-Band Flow Control Interface Signals (Part 2 of 2)

Signal Direction

Description

Table 5–10. RX Out-of-Band Flow Control Block Signals for Application Use

Signal Direction

Description

rx_oob_in_sys_clk

(1)

Input

Reference clock for capturing RX calendar, lane status, and link
status. Frequency must be at least double the frequency of
rx_oob_in_fc_clk

.

rx_oob_in_sys_arst

Input

Asynchronous reset for the out-of-band RX block.

rx_oob_out_status_update

Output

Indicates a new value without CRC-4 errors is present on at least one
of rx_oob_out_lane_status or rx_oob_out_link_status in the
current rx_oob_in_sys_clk cycle. The value is ready to be read by
the application logic.

rx_oob_out_lane_status[L:0]

Output

Lane status bits received from an upstream out-of-band TX block on
rc_oob_in_fc_data

.

Width is the number of lanes (L = num_lanes – 1).

rx_oob_out_link_status

Output

Link status bit received from an upstream out-of-band TX block on
rc_oob_in_fc_data

.

rx_oob_out_status_error

Output

Indicates corrupt lane or link status. A new value is present on at least
one of rx_oob_out_lane_status or rx_oob_out_link_status
in the current rx_oob_in_sys_clk cycle, but the value has at least
one CRC-4 error.

rx_oob_out_calendar[15:0]

Output

Calendar bits received from an upstream out-of-band TX block on
rc_oob_in_fc_data

.

rx_oob_out_calendar_update

Output

Indicates a new value without CRC-4 errors is present on
rx_oob_out_calendar

in the current rx_oob_in_sys_clk cycle.

The value is ready to be read by the application logic.

rx_oob_out_calendar_error

Output

Indicates corrupt calendar bits. A new value is present on
rx_oob_out_calendar

in the current rx_oob_in_sys_clk cycle,

but the value has at least one CRC-4 error.

Note to

Table 5–10

:

(1) Altera recommends that you run rx_oob_in_sys_clk at 200 MHz, to support the recommended (and maximum allowed) rx_oob_in_fc_clk

frequency of 100 MHz.