Signal

Width

Clock Domain

Direction

Description

sync_tx

8

Standard

clocking:

user_clock
Advanced

clocking:

core_clock

Input

The sync vector is an 8 bit bus. The data

value at the start of a burst and at the end of a

burst are captured and transported across the

link.
Note: This vector is not associated with

Interlaken channelization or flow

control schemes.

valid_tx

1

Standard

clocking:

user_clock
Advanced

clocking:

core_clock

Input

This vector indicates that the data is valid.

start_of_burst_

tx

1

Standard

clocking:

user_clock
Advanced

clocking:

core_clock

Input

When the core is in burst mode operation,

assertion of this signal indicates that the

information on the data vector is the

beginning of a burst.
Because continuous mode is one long burst,

in this mode the signal is asserted only once

at the start of the data.

end_of_burst_tx

1

Standard

clocking:

user_clock
Advanced

clocking:

core_clock

Input

When the core is in burst mode operation,

assertion of this signal indicates that the

information on the data vector is the end of a

burst.