1.5 General safety instructions on installing and operating the refrigerated

incubator

With regard to operating the refrigerated incubator KT and to the installation location, please observe the

guideline BGI/GUV-I 850-0 on safe working in laboratories (formerly BGR/GUV-R 120 or ZH 1/119

laboratory guidelines issued by the employers’ liability insurance association) (for Germany).
BINDER GmbH is only responsible for the safety features of the unit provided skilled electricians or

qualified personnel authorized by BINDER perform all maintenance and repair, and if components

relating to chamber safety are replaced in the event of failure with original spare parts.
To operate the unit, use only original BINDER accessories or accessories from third-party suppliers

authorized by BINDER. The user is responsible for any risk caused by using unauthorized accessories.

CAUTION

Danger of overheating.
Damage to the unit.

Do NOT install the unit in unventilated recesses.

Ensure sufficient ventilation for dispersal of the heat.

Do not operate the refrigerated incubator KT in hazardous locations.

DANGER

Explosion hazard.
Danger of death.

Do NOT operate the unit in potentially explosive areas.

KEEP explosive dust or air-solvent mixtures AWAY from the unit.

The refrigerated incubator KT does not dispose of any measures of explosion protection.

DANGER

Explosion hazard.
Danger of death.

Do NOT introduce any substance into the refrigerated incubator which is combustible or

explosive at working temperature.

NO explosive dust or air-solvent mixture in the inner chamber.

Any solvent contained in the charging material must not be explosive or inflammable. I.e., irrespective of

the solvent concentration in the steam room, NO explosive mixture with air must form. The temperature

inside the chamber must lie below the flash point or below the sublimation point of the charging material.

Familiarize yourself with the physical and chemical properties of the charging material, as well as the

contained moisture constituent and its behavior with the addition of heat energy.
Familiarize yourself with any potential health risks caused by the charging material, the contained

moisture constituent or by reaction products which may arise during the temperature process. Take

adequate measures to exclude such risks prior to putting the refrigerated incubator into operation.

DANGER

Electrical hazard.
Danger of death.

The unit must NOT become wet during operation or maintenance.

The refrigerated incubators were produced in accordance with VDE regulations and were routinely tested

in accordance to VDE 0411-1 (IEC 61010-1).