Commands

the drawing area. When proximity is off, active pointers remain on-screen
when the pen is lifted.

(R) Restart Pointmaker

The “R” command restarts the Pointmaker. Options include saving current set-
tings and markers in memory (a soft boot), or clearing memory of all settings
and markers (a hard boot).

(S) Date/Time Marker

The “S” command controls options concerning the date/time marker. It dis-
plays as an active marker.

(SU) Port Initialization

The “SU” command controls COMM port detection on start-up. It can also
activate the autodetection process immediately.

<Esc>(PX1

Turn proximity on.

<Esc>(PXØ

Turn proximity off.

<Esc>(PXT

Toggle proximity.

<Esc>(RS

Restart saving current settings and markers in memory.

<Esc>(RH

Restart clearing current settings and markers.

<Esc>(STØ

Displays date/time marker in time only mode.

<Esc>(SDØ

Displays date/time marker in date only mode.

<Esc>(SDT

Displays date/time marker in time only mode.

<Esc>(SDSMMDDYYYY

Set the date.
M=month, D=Day, Y=year

<Esc>(STAHHMM

Set time as a.m.
H=hour, M=minute

<Esc>(STPHHMM

Set time as p.m.
H=hour, M=minute