Daktronics Pro Series Operations and Maintenance Manual User Manual

Page 57

Advertising
background image

50

Figure 7.47: Sensitivity has been adjusted

Figure 7.48: Motor 0 fault is cleared. Cues with

Motor 0 return to normal display.

Figure 7.49: From the alert box, BYPASS selected.

Figure 7.50: Cue action 2.00 with the safety feature

bypassed

When the motor’s sensitivity is changed, the

ADJUST button will activate (Figure 7.47).

Touch ADJUST to confirm change.

Touch FINISH MOVE to complete the move in

which the batten faulted (Figure 7.48).
To clear the fault without finishing the move, hide

the Alert box by touching the ALERT button. This will

clear the fault without moving the batten. When the

box is displayed again, the fault will be cleared.
The Clear Fault function works for one move only. A

motor that keeps overloading or underloading may

need to have the i-Batten function bypassed or its

sensitivity adjusted.

Bypass

To bypass the i-Batten Safety feature and complete

a move, select a motor by touching its name in the

list. Touch BYPASS and the panel will display a

CONFIRM button (Figure 7.49). Touch CONFIRM

and FINISH MOVE. Bypassed motors display an

i-Batten Safety Off icon at the left of cue actions

where the motor is used as illustrated in Figure 7.50.

This will disable the i-Batten safety feature for this

motor. i-Batten can be re-enabled only from the Setup

module which requires Administrator privileges.

WARNING

Bypassing the i-Batten safety feature

will remove the ability of the VAC

to report a faulted condition

during operation.