5. Set the maximum speed of the motor using

the slider control (Figure 9.8).

Depending on what is attached to the batten,

you may wish to limit how fast the motor can

move. By dragging the slider change the

motor’s maximum speed can be changed.

6. The i-Batten sensitivity value determines how

much the batten’s weight must change to

register a fault.

Touch SET SENSITIVITY (Figure 9.9) to

display a keypad to enter the sensitivity value

(Figure 9.10). After entering the sensitivity,

i-Batten system is ready for the teach setup.

WARNING

The cables are rated for 420 lbs.

of support. Overloading the batten

could cause the cables to break.

Figure 9.8: Maximum speed slider

Figure 9.9: Set Sensitivity button

Figure 9.10: Sensitivity keypad