Included Safety Features

i-Batten with Over-load and Under-load Protection

The i-Batten feature allows the authorized operator to preset sensitivity on the maximum and minimum

loads a specific Vortek hoist will encounter. If the system detects a load outside the set range, indicating

a possible problem, the unit will automatically stop all motion. It is strongly recommended that this feature

be used in order to prevent any injury to personnel or damage to equipment.

Emergency Stop

A red Emergency Stop mushroom head push button is located on each VAC control station. Pushing

the button will disable all motor drives connected through the specific VAC, and set all motor brakes.

This will stop all motion of the attached loads on each Vortek hoist immediately, and inhibit further

movement until reset.
The Emergency Stops should ONLY be used for real emergencies or when required to reset a motor fault

if indicated on the VAC touchscreen.

Vortek Back-Up brake

This secondary mechanical braking system is designed to hold the rated load in the improbable case of

a failure of the primary motor brake or gearbox. This system acts independently of any electrical inputs

on the system.

Compliance with Regulations

The Daktronics system complies with the relevant European directives required for the CE mark, including:

98/37/EC: Machinery Directive

73/23/EEC: Low Voltage Directive

89/336/EEC: Electromagnetic Compatibility

Independent reviews/tests in support of above compliance

EN55022 Class A Radiated and Conducted Emissions

EN61000-4-2 Electrostatic Discharge

EN61000-4-6 Conducted Susceptibility

EN60950, 60204 Safety Review

Airborne noise emissions

Continuous A-weighted sound pressure levels at distances 40 feet from the Vortek hoist module,

a typical distance for the operator VAC control unit to be located, do not exceed 70 decibels.