7. Touch TEACH DOWN. A new panel displays

(Figure 9.11).

To teach the i-Batten System, the batten must

travel for a length of time. The proper way to

ensure the motor has enough time to travel

is to start at the opposite limit. At this point

in the instructions, the batten is at the upper

limit so the i-Batten is is ready to be taught

down. Touch TEACH DOWN.

The batten will start travelling downward.

In an emergency, touch STOP to halt the

motor's movement and suspend the

teaching. Touch UPPER LIMIT and

teach the i-Batten again.

When the i-Batten system is successfully

taught, the batten will automatically stop.

Touch CONTINUE. Return to the Batten

Setup screen.

8. On the Batten Setup screen (

Figure 9.7),

touch TEACH UP. A new panel displays

(Figure 9.12).

Touch LOWER LIMIT to move the batten to

its lower limit and ensure it has enough room

to be taught. When the batten has reached

its lowest point, touch TEACH UP.

The batten will start travelling up. Touch

CONTINUE when the batten has stopped

moving.

i-Batten teaching is now complete for this motor.

WARNING

Because this is an automatic

procedure, the area underneath the

batten must be clear of people and

obstructions before this operation is

attempted. During this procedure the

i-Batten safety feature is off.