snmp-server location xxx command is used to set the location information for this
switch. “xxx” is the location information string.
snmp-server version x command is used to select the SNMP operation version. “x
could be v1, v2c, v3, v3v2c, v3v2cv1.

The following commands are for SNMPv3 function.
snmp-server username xxx securitylevel y command is used set security level of user
xxx. “xxx” is the user name. “y” could be noauth, auth, or priv.

-

“noauth” : no authentication, no encryption

-

“auth” : do authentication, no encryption

-

“priv” : do authentication and encryption(by DES)

snmp-server username xxx authentication y command is used to set the
authentication manner. “xxx” is the user name. “y” could be md5 or sha.



29 sntp command

This command is used to configure SNTP protocol of the switch.
Entering “sntp ?”, the sub-commands will be shown.

(config)# sntp ?
client

Accepts time from specified time server

server

Specified one time server

zone

Set time zone

dst

Config daylight saving time function.

start-time Set start time of daylight saving time
end-time Set end time of daylight saving time


sntp client command is used to enable SNTP protocol. And no sntp client command
can be used to disable it. If it is disabled, the system time will be got from manual
setting.
sntp server x.x.x.x command is used to set the IP address of network time server for
SNTP protocol operation. “x.x.x.x” is the IP address.
sntp zone xxx command is used to set the time zone. “xxx” is the location of the time
zone. With “sntp zone ?”, the locations will be shown.
sntp dst command is used enabled Daylight Saving Time function. And no sntp dst
command can be used to disabled it. Daylight Saving Time function will set the system
time one-hour early than normal time in a period of time. “start-time” and “end-time”
sub-commands can be used to set the time period.
sntp start-time w/x/y/z command is used to set the start time of Daylight Saving
Time.

-

w” is the week number in the month. Its value is 1~5.

-

x” is the day number in the week. Its value is 0~6.

-

y” is the month number. Its value is 1~12.

-

z” is the hour number in the day. Its value is 0~23.

sntp end-time w/x/y/z command is used to set the end time of Daylight Saving Time.

-

w” is the week number in the month. Its value is 1~5.

-

x” is the day number in the week. Its value is 0~6.

-

y” is the month number. Its value is 1~12.